beautypg.com

Res 5.00 ppm [••••• ] set, 0 0 0 ent, Cal alm rng run – Eagle Microsystems RA1000 User Manual

Page 14: Cell out esc

background image

14

MAIN RUN SCREEN

The value displayed is the chlorine residual in ppm or mg/l. Below the residual value is a fifty segment
bar-graph representation of the residual 4mA to 20mA output (PO1).

RES 5.00 ppm

[••••• ] SET

1

no label

Displays the water temperature.

4

SET

The user is prompted to enter a password to enter a programming mode in which
one can calibrate, set alarm set-points, and set the 4-20mA output range.

PASSWORD ENTRY SCREEN

ENTER PASSWORD

0 0 0 ENT

RESIDUAL SETUP MENU

From the run screen, press SET and the user will be prompted to enter the password (default

is 000). If the entered password is correct, the residual setup (calibration, alarm, & range) menu will be
displayed.

RESIDUAL SETUP

CAL ALM RNG

RUN

1

CAL

Enter calibration menu

2

ALM

Set the high and low residual alarm setpoints

3

RNG

Set the 4-20mA output range.

4

RUN

Go back to the main run screen

CALIBRATE

CELL OUT
ESC

1

CELL

Calibrate cell

2

No function

3

OUT

Calibrate the 4-20mA output.

4

ESC

First, the operator is prompted to enter a new password and then is returned to the
residual setup menu.