beautypg.com

3 input / output signals, 1 input / output signals – Citizen Systems CBM-231 User Manual

Page 22

background image

CBM-230/231 User’s Manual

17

CITIZEN

6.3

Input / Output Signals

6.3.1 Input / Output Signals

(1) Input signals to the printer

DATA

: This is an 8-bit parallel signal (Positive logic)

STB

: This is a strobe signal to read in 8 -bit data (Negative logic)

RESET

: This signal resets the entire printer (Negative logic) 1 ms or more

(2) Output signals from the printer

ACK

: This is an 8-bit data request signal. Pulse signal output at the end of the BUSY signal

(Negative logic)

BUSY

: This signal indicates the BUSY state of the printer. Enter new data when it is at LOW.

(Positive logic)

FAULT

: This signal is set to low when the printer has an alarm. When this is done, all control

circuits in the printer stop.(Negative logic)

PE

: This signal is output when the printing paper has run out or is running out.

(Positive logic)

Drawer switch output

: This signal is set to HIGH when the switch is opened, and to LOW when shorted.

(3) Power signals

+5VDC

: This is a 5 V output pulled up at a 3.3 k

resistor.

GND

: This is a common ground on the circuits.