Comtrol VS2000 V.34 User Manual
Page 2
![background image](/manuals/672046/2/background.png)
Note: If using an AUI connection to the server, you can
determine proper polarity by using an AUI to
10Base-T converter box.
Modem Cables
The VS2000 modem ports use standard telephone-type
unshielded twisted-pair cables with RJ11 modular
connectors. These cables can be purchased anywhere
commercial or consumer telephone products are sold.
If you choose to build your own cables, use the following
information:
The connector pinouts are as shown below:
When building cables, use Category 3 (or better)
unshielded wiring.
Ethernet Crossover Cable
If you are connecting from the VS2000 10Base-T
connector directly to the NIC card in the server, you
need a crossover cable, wired as follows:
Remote Connector
The DB9 port labeled “Remote” is reserved for Comtrol
Corporation repair and maintenance use. No user-
accessible signals are present on this port.
Operating Conditions
This table illustrates VS2000 operating conditions:
Electromagnetic Compliance
This table lists electromagnetic compliance
certifications:
LED
Light
10Base-T LED Description
U
p
p
e
r
Flashes
Briefly
During the power on cycle (first few
seconds after the power is turned on),
this LED flashes briefly to display link
polarity on the 10Base-T connection.
U
p
p
e
r
Flashing
The light flashes briefly during
transmissions as a general indicator of
activity.
L
o
w
e
r
On
VS2000 is correctly attached to the
LAN by the RJ45 10Base-T connector.
L
o
w
e
r
Off
VS2000 is not connected to the LAN
properly or it is connected to the AUI
port.
Indicator
Ports 1 through 8 LED Description
Flash
Briefly
All LEDs light briefly during the power-on
sequence and then turn off.
1 LED Lit* RAM self-test failure or mainboard error.
2 LEDs Lit* Ethernet hardware initialization failure.
3 LEDs Lit* A hardware self-test failure.
4 LEDs Lit* A flash memory configuration error.
All
Flashing/
Individual
Flashing
All LEDs on for about 0.5 seconds then
one or more individual port LEDs on for
about 0.5 seconds indicates that the
individual port or ports, whose LED is
flashing, encountered a problem during
port/modem initialization.
* The LEDs light up for a about a minute and then the
hardware resets and the same cycle repeats.
Pins
RJ11 Connector Signals
1
Not used
2
Ring
3
Tip
4
Not used
Pin 1
Pin 4
Table 1. Ethernet Crossover Cable
Pin
Connects to Pin
1
3
2
6
3
1
6
2
Environmental Condition
Value
Air temperature:
System on
System off
0 to 40
o
C
-20 to 85
o
C
Altitude
0 to 10,000 feet
Humidity (non-condensing):
System on
System off
8% to 80%
20% to 80%
Electromagnetic Compliance
Status
Canadian EMC requirements
Yes
FCC Class A certification
Yes
FCC Part 68 certification
Yes
Ringer Equivalency Number
0.8B
UL Listed
Yes
Surge protection
ESD surge protection
exceeding 20 KV
Pin 1
Pin 8
Receptacle
Pin 1