background image

Note: If using an AUI connection to the server, you can

determine proper polarity by using an AUI to
10Base-T converter box.

Modem Cables

The VS2000 modem ports use standard telephone-type
unshielded twisted-pair cables with RJ11 modular
connectors. These cables can be purchased anywhere
commercial or consumer telephone products are sold.

If you choose to build your own cables, use the following
information:

The connector pinouts are as shown below:

When building cables, use Category 3 (or better)
unshielded wiring.

Ethernet Crossover Cable

If you are connecting from the VS2000 10Base-T
connector directly to the NIC card in the server, you
need a crossover cable, wired as follows:

Remote Connector

The DB9 port labeled “Remote” is reserved for Comtrol
Corporation repair and maintenance use. No user-
accessible signals are present on this port.

Operating Conditions

This table illustrates VS2000 operating conditions:

Electromagnetic Compliance

This table lists electromagnetic compliance
certifications:

LED

Light

10Base-T LED Description

U

p

p

e

r

Flashes

Briefly

During the power on cycle (first few
seconds after the power is turned on),
this LED flashes briefly to display link
polarity on the 10Base-T connection.

U

p

p

e

r

Flashing

The light flashes briefly during
transmissions as a general indicator of
activity.

L

o

w

e

r

On

VS2000 is correctly attached to the
LAN by the RJ45 10Base-T connector.

L

o

w

e

r

Off

VS2000 is not connected to the LAN
properly or it is connected to the AUI
port.

Indicator

Ports 1 through 8 LED Description

Flash

Briefly

All LEDs light briefly during the power-on
sequence and then turn off.

1 LED Lit* RAM self-test failure or mainboard error.

2 LEDs Lit* Ethernet hardware initialization failure.

3 LEDs Lit* A hardware self-test failure.

4 LEDs Lit* A flash memory configuration error.

All

Flashing/

Individual

Flashing

All LEDs on for about 0.5 seconds then
one or more individual port LEDs on for
about 0.5 seconds indicates that the
individual port or ports, whose LED is
flashing, encountered a problem during
port/modem initialization.

* The LEDs light up for a about a minute and then the

hardware resets and the same cycle repeats.

Pins

RJ11 Connector Signals

1

Not used

2

Ring

3

Tip

4

Not used

Pin 1

Pin 4

Table 1. Ethernet Crossover Cable

Pin

Connects to Pin

1

3

2

6

3

1

6

2

Environmental Condition

Value

Air temperature:

System on
System off

0 to 40

o

C

-20 to 85

o

C

Altitude

0 to 10,000 feet

Humidity (non-condensing):

System on
System off

8% to 80%

20% to 80%

Electromagnetic Compliance

Status

Canadian EMC requirements

Yes

FCC Class A certification

Yes

FCC Part 68 certification

Yes

Ringer Equivalency Number

0.8B

UL Listed

Yes

Surge protection

ESD surge protection
exceeding 20 KV

Pin 1

Pin 8

Receptacle

Pin 1