Hardware installation, Setting the dip switch – Comtrol ES7110-VB User Manual
Page 7
Hardware Installation
RocketLinx ES7110 and ES7110-VB User Guide: 2000552 Rev. C - 7
Hardware Installation
You can use the following subsections to install the RocketLinx ES7110:
•
•
•
Wiring the Relay Output and Ground
•
Mounting the RocketLinx ES7110
•
•
Setting the DIP Switch
The ES7110 has a 10-pin DIP switch located on the bottom of the switch to configure the Port Link Alarm for the Ethernet
ports. The following table shows the DIP switch number mapping to the corresponding PoE and Gigabit ports as follows.
Port G2
Port G1
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
Port 7
Port 8
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
DIP 9
DIP 10
DIP Switch Number
Status
Description
1-2
On
Enables the Gigabit port link failure alarm for this port.
Off
(Default)
Disables the Gigabit port link failure alarm for this port.
3-10
On
Enables the PoE port link failure alarm for the
corresponding port.
Off
(Default)
Disables the PoE port link failure alarm for the
corresponding port.