Crestron electronic CLW-SW1/4RF User Manual
Page 6

infiNET™ Switches
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
infiNET Gateway and, if more devices are needed, more C2N-MNETGW gateways 
may be added to a Cresnet
®
network.
Crestron infiNET switches operate on the 2.4 GHz “ISM band” (2400 MHz to 
2483.6 MHz) at 10 mW. The output power of these devices allow RF signals to 
travel approximately 150 feet indoors and 250 feet outdoors (subject to site-specific 
conditions) without the use of repeaters or other infiNET devices. The range is 
dependent on construction of the building, obstructions, and RF interference from 
other devices. The location of the switch is an important factor in determining RF 
performance. Adding more infiNET devices or repeaters to the network effectively 
increases the range, strength, and reliability of the network. 
The -SW1RF and -SW4RF feature a three-position mode selection switch. Refer to 
“Operation” on page 10 for more information. In the absence of control system 
communications, the switch can still be used to control the attached load. 
The CLW-SWS1RF (-SWS1RF) and CLW-SWS4RF (-SWS4RF) are similar to the 
-SW1RF and -SW4RF (respectively) with the added capability of working with one 
or more slave units (CLW-SLVS1RF) in a multi-switch / single circuit application. 
For more information, refer to the latest version of the infiNET Switches Installation 
Guide (Doc. 6293) which is available from the Crestron website 
(www.crestron.com/manuals). 
The CLW-SLVS1RF (-SLVS1RF) is a slave unit that when used in conjunction with 
the -SWS1RF or -SWS4RF acts as an additional switch control point in a multi-
switch / single circuit application. It does not connect to an infiNET system and 
cannot be used without a -SWS1RF or -SWS4RF. The -SLVS1RF does not have a 
mode selection switch. It can only be programmed when used in conjunction with a 
-SWS4RF (refer to the SIMPL™ Windows
®
help file). Otherwise, it will emulate the
RUN mode of the -SWS1RF (even if connected to a -SWS4RF) unless the mode 
selection switch of the master is set to “OFF”. 
These switches can be ordered with custom engraved buttons already installed by 
Crestron. Engraved buttons cannot be installed or changed in the field. Contact 
Crestron for more information. 
These switches are available in a variety of colors and textures. The table below 
shows the availability. 
Available Colors/Textures
COLOR/
TEXTURE
MODEL NUMBER
SUFFIX
MATCHING FACEPLATE
(Lutron
®
Part Number Shown
White W
Not
Applicable
Smooth White
W-S
CW-1-WH
Almond A
CW-1-LA
Smooth 
Almond 
A-S
CW-1-LA
Black B
Not
Applicable
Smooth Black
B-S
CW-1-BL
For installation instructions, refer to the latest version of the infiNET Switches 
Installation Guide (Doc. 6293), which is available from the Crestron website. 
2
• infiNET Switches: Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
Operations Guide - DOC. 6397A