Crestron electronic CLW-SW1/4RF User Manual
Page 28

infiNET™ Switches
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
• The system tree of the control system displays the device in the appropriate
slot with a default MNET ID as shown in the following illustration.
C2Net Device, Slot 6, with infiNET Device
SIMPL Windows adds the selected infiNET device with a default MNET
ID. Following are the default MNET IDs used by SIMPL Windows for each
of the switch models:
• CLW-SW1RF: 07
• CLW-SW4RF: 09
• CLW-SWS1RF: 08
• CLW-SWS4RF: 0A
NOTE: The default MNET ID used by SIMPL Windows is different from
the default ID that is installed on an infiNET device when it ships from the
factory.
NOTE: If the default MNET ID is already in use, SIMPL Windows will
assign the next available MNET ID.
NOTE: infiNET repeaters such as the C2N-MNETRPT are not added in
SIMPL Windows as there is no control communication between a control
system and a repeater.
• If necessary, double click a device to open the “Device Settings” window
and change the MNET ID, as shown in the following figure.
“Device Settings” Window for the CLW-SW1RF
24
• infiNET Switches: Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
Operations Guide - DOC. 6397A