Consult with the service shop or authorized personnel
The following will change wiring conditions inside the camera head. We recommend
you to use the service shop or authorized service personnel.
(B) Changing from left side to right side
Changing from left side
to right side
Procedures
Description on
procedures
From left side @
To right side®
Turn to right with 180°
1. Remove 2 securing
screws on the back panel.
2. Pull out flexible PC board
from back panel, and
rotate entire back panel
by 180° in clockwise
direction (take care not to
break wiring leads).
3. Restore flexible PC board
on back panel again and
firmly tighten 2 screws.
Cautions:
• Take care not to apply tension and torque exceeding 180° to the wiring material,
because this may change wiring conditions inside the unit. Also take care not to
twist the flexible PC board. If twisted, it may cause break down of wiring leads or
damage circuits inside the camera head
• (A) and (B) will be made in combination as required.