BRUSH SERVICING

A

WARNING

Electrical Shock Or Personal Injury
Hazard

Disconnect electrical supply before
servicing or cleaning the unit
Failure to do so could result in elec­

trical shock or personal injury from

cleaner suddenly starting.

TO CHECK BRUSHES

When brushes
are worn to the
level of the base
support bars»
replace the
brush dowel.

TO REPLACE BRUSH DOWEL

1. Remove Power-Mate® cover, belt and
brush assembly, See "To Remove Belt" in
BELT CHANGING AND BRUSH
GLEANING.

2. Remove brush supports, washers,
screws, end brush, brush sprocket pieces
from ends of brush assembly.

3. Reassemble brush assembly. To line up
screw holes in dowei, sprocket and end
brush, be sure the brush portion of end
brush lines up with brushes on brush dowel

4. Replace belt, brush assembly, Power­

Mate® cover, light bulb and Jighi cover. See

"To replace belt” in BELT CHANGING AND

BRUSH GLEANING.

BRUSH ASSEMBLY