C. rotary valve service, Disassembly, Servicing the valve – Kenmore TANNIN 625.348261 User Manual
Page 22: Assembly, Rotary valve service -4, Service tech. information
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SECTION 5
SERVICE TECH. INFORMATION
C. ROTARY VALVE SERVICE
IMPORTANT:
Before working on the valve, turn
off the water supply and disconnect from electrical
power.
To relieve pressure:
.. . THREE VAEVE BYPASS: Close the inlet and
open a filtered water faucet. Then close the outlet
valve and open the bypass valve.
.. . SEARS SPECIAE BYPASS: Slide the bypass
valve stem to bypass position. Loosen the three
hex head screws (see (g) in drawing) toward the
backside of the valve to allow pressure water to
bleed out (catch water with a rag).
DISASSEMBLY
To remove a part or group of parts, refer to the
valve drawing. A common screwdriver or nut
driver, Phillips screwdriver and pliers are the only
tools needed to completely disassemble.
SERVICING THE VALVE
Inspect all o- rings, seals and gaskets for wear or
defects.
Inspect the bottom surface of the rotor and disc for
scratches, chips or wear.
NOTE:
If a replacement is needed, be sure to use
the current replacement part.
ASSEMBLY
Be sure all parts are in place and in the proper
position. Lubricate ALL o- rings, and seals with
FDA approved silicone grease. To install the rotor
seal, first place the seal into the valve groove,
round side down (see cross section). Apply a light
coating of silicone grease to the seal's crossing
ribs. Then carefully center the wear strip on the
seal, and push it downward onto the seal.
Install the nozzle and venturi seal and drain seal.
Assemble two o-rings and the wave washer onto
the rotor and disc. The center the rotor and disc, in
the valve body, on the rotor seal.
Lower the cover onto the valve body and rotor
shaft. Then install the cover holding screws.
Before tightening the screws, install the valve cam
and gear, then turn the rotor (clockwise only) to
service postion.
spacer
switch
motor plate
flow plug {back
wash and fast rinse
flow rate control)
rotor & disc
o-nng
rotor seal
drain seal
nozzle and
venturi seal
Tighten the screws using a criss-cross pattern. If a
torque wrench is available, torque to 30-40 inch
pounds.
Lubricate the gear on the motor, and the valve
cam gear with Molykote grease, or other high
quality gear lubricant.
Be sure to orient switch as shown, with lever to
ward the valve cam.
5-4
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line