beautypg.com

Vent pipe system, Draft hood installation, Draft hood installation -20 – Kenmore ELITE 153.33264 User Manual

Page 19

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Gable Vent

All Air From Outdoors: Inlet Air From Ventilated

Crawl Space/Outlet Air To Ventilated Attic

FIGURE 15.

Gable Vent
to Outdoors

All Air from Outdoors Through Ventilated Attic

FIGURE 16.

All Air From Outdoors Using Horizontal Ducts

FIGURE 17.

All Air From Outdoors - Using A Single Permanent Opening

FIGURE 18.

Vent Pipe System

This water heater uses a non-direct, single-pipe vent system to
remove exhaust gases created by the burning of fossil fuels. Air
for combustion is taken from the immediate water heater location
or is ducted in from the outside (see “Combustion Air Supply and
Ventilation”).
This water heater must be properly vented for the removal of
exhaust gases to the outside atmosphere. Correct installation of
the vent pipe system is mandatory for the proper and efficient
operation of this water heater and is an important factor in the life
of the unit.
The vent pipe must be installed according to all local and state
codes or, in the absence of local and state codes, the “National

Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition. The

vent pipe installation must not be obstructed so as to prevent the
removal of exhaust gases to the outside atmosphere.

IMPORTANT: The use of vent dampers is not recommended

by the manufacturer of this water heater. Although some vent
dampers are certified by CSA International, this certification
applies to the vent damper device only and does not mean they
are certified for use on this water heater.
U.L. recognized fuel gas and carbon monoxide (CO) detectors
are recommended in all applications and should be installed
using the manufacturer’s instructions and local codes, rules, or
regulations.

IMPORTANT: If you lack the necessary skills required to properly
install this venting system, you should not proceed, but get help

from a qualified technician.

Draft Hood Installation

50 GAL. UNIT

4

Flat Side Of Hootr*l

Next To Water V.

Connections.

^

40 GAL. UNIT

Flat Side Of Hood

Next To Water

Connections.

Installation above —

elevation 5,400 ft.

(1,646 m) from sea
level, Reducer Flue ^
must be installed on ^

40 gallon unit.

Screw , Legs

^ Draft Hood

S l o t T o p —Slot

Install The Draft Hood With The Four Screws Provided.

fc./

\

!■

Screw

Legs.

—Draft Hood

.

~ Reducer Flue

^Legs

Slot ^-Top

*—Slot

Install The Draft Hood With The Four Screws Provided.

FIGURE 19.

19

This manual is related to the following products: