Gas pipe capacity table, Explosion hazard, Warning – Kenmore ELITE 153.33264 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Gas Pipe Capacity Table

A

WARNING

U/

Explosion Hazard

Use a new CSA approved gas supply line.

Install a shut-off valve.

Do not connect a natural gas water heater to an L.P. gas

supply.

Do not connect an L.P. gas water heater to a natural gas

supply.

Failure to follow these instructions can result in death,

explosion, or carbon monoxide poisoning.

A

WARNING

U/

Explosion Hazard

• Gas leaks can not always be detected by smell.

• Gas suppliers recommend that you use a gas

detector approved by UL or CSA.

• For more information, contact your gas suppiier.

• if a gas ieak is detected, foiiow the “What to do if you

smeii gas” instructions on the cover of this manuai.

Table 1

Natural Gas Pipe Capacity Table (Cu. Ft/Hr.)

Captidty of gas pipe of different diamolers and longlhs in cu. ft. per hr. with pressurei drop of 0.3 in. and specific gravity
of 0.60 (natural gas.)

Nominal Iron Pipe

Jfi____40

50

Length of Pipe. Feet

1/2

132

92

73

63

56

50

46

43

40

38

34

31

28

26

3/4

278

190

152

130

115

105

96

90

84

79

72

64

59

55

1

520

350

285

245

215

195

180

170

160

ISO

130

120

110

100

1-1/4

1050

730

590

500

440

400

370

350

320

305

275

250

225

210

1-1/2

1600

1100

890

760

670

610

560

530

490

460

410

380

350

320

After the length of ppe has Penn determinBri, select the p-pe Size which will provide the minimum cubic feet per hour

required for the gas input rating of the water beater.

By

formula:

Mid, CU. Ft. Per Hr Required^

^

Heating Value of Gas (BTU/FP)

I ho gas

input

of the water heater

is

rparked

on the

water heater data plate.

The

haatiog value of the gas (BTU/FT)

may be detorminod by consulting the local natural gas utility.

Table 2

LP Gas Capacity Table

Maximum capacity of pipe in thousands of BTU per hour of unroluieo, liquefied petroleum gases {at 11 inches water
coiumn pressure.) Based on a pressure drop of 0.5 inch water coiymn.

Nominal Iron Pipe

Size, in. .

Length of Pipe. Feet

1/2

275

189

152

129

114

103

96

89

83

78

69

63

3/4

576

393

315

267

237

217

196

185

173

162

146

132

1

1071

732

590

504

448

409

378

346

322

307

275

252

1-1/4

2205

1496

1212

1039

913

834

771

724

677

630

567

511

Example: Input BTU requirement of the water heater 100.000 BTUH.

Total pipe length. 80 feet = 3/4" IPS required.

Additional tables are availaWe in the latest edition of the "National Fuel Gas Code", ANSÍ Z223.1.

16