DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
In an area where it will conne in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
On carpet. Floor MUST be solid with a maximum slope of 1
inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the
same closet as the Gas dryer.
Your dryer needs the space around it for proper ventilation.
DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A
SOLID DOOR.
3.
4. A minimum of 120 square inches (JlA.l square cm) of
opening, equally divided at the top and bottom of the door,
is required. Air openings are required to be unobstructed
when a door is installed. A louvered door with equivalent
air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
FRONT SIDES REAR TOP
Alcove
0 (0 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet
1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15(38.1 cm)
Closet door ventilation required: 2 louvered openings each 60
square inches (387 square centimeters) — 3 inches (7.6 cm)
from bottom and top of door.
THIS DRYER MUST BE EXHAUSTED OUTDOORS.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
Rigid
Metal
Only
Rigid
Metal
Only
Rigid
Metal
Only
Correct
Correct
6
Correct