Customer Responsibilities

Thank You

for purchasing a Sears water heater.

Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed, contact the local Sears
Service Center or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual

U.L. - Underwriters Laboratories Inc.
NEC - National Electrical Code

ANSI - American National Standards Institute

Product Specifications

MODEL

NUMBER

TANK

CAPACITY

IN GALLONS

DIMENSIONS IN INCHES

RECOVERY RATE

GALS. PER HOUR

@90®E RISE

ELEMENT

WATTAGE

AT 240 VOLTS

MINIMUM

WIRE SIZE*

(GAUGE)

MAXIMUM FUSE

OR CIRCUIT

BREAKER

SIZE (AMPS)

DIAMETER HEIGHT

UPPER

LOWER

153.326360

153.326361

30

18

4672

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326460

153.326461

40

18

597

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326560

153.326561

50

20/2

607

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326660

153.326661

50

23

49

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326760
153.326761

40

20/2

44

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.326860

153.326861

50

26/2

34

17.3

3800

3800

12

20

25.0

3800

5500

10

30

*Wiring size based on standard 60“C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical

code.

Preparing for the New Installation

Read the “Safety Precautions” .section, page 2 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could

cause

DEATH,

SERIOUS

BODILY

INJURY

AND/OR PROPERIT DAMAGE.

This manual contains instructions for the installation, opera­
tion, and maintenance of this electric water heater, it also
contains warnings throughout the manual that you must read
and be aware of All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, READ
THIS ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the
NEC, National Electrical Code, NFPA 70. This publication
is available from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do not
understand any portion of the instructions, call Sears Service
Center.
Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock
and fires.
Examine the location to ensure the water heater complies

with the “Facts to Consider About the Location” section.

For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce­
dures. Instructions may be obtained from the California office
of the State Architect, 400 P Street, Sacramento, CA 95814
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248-CMR 2.00: State
Plumbing Code and 248-CMR 5-00.