Converting the lower element (cont'd), A warning, A caution – Kenmore POWER MISER 153.32676 User Manual
Page 12: Installation instructions (cont’d)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/665617/12/background.png)
Converting the Lower
Element (cont'd)
9- Replace terminal cover on thermostat making sure that the
locking tabs on the terminal cover are in place.
Installation Instructions (cont’d)
12. Complete wiring to the water heater, or if completed, turn
“ON” electric power to the water heater after filling the
tank with water.
A WARNING
Make sure the thermostat is flush against the tank, the
terminal cover is in place, and the insulation is replaced.
Failure to do so can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.
10. Replace the insulation block and pad so that it completely
covers the thermostat and element.
A CAUTION
Never use this water heater unless it is completely full of
water. To prevent damage to the tank and heating ele
ment, the tank must be filled with water. Water must
flow from the hot water faucet before turning “ON”
power.
11. Replace the access panel.
12