Warning, Electrical shock or personal injury hazard – Kenmore 11 User Manual
Page 18
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
1. Remove Power-Mate® cover as shown in
BELT CHANGING AND AGITATOR CLEAN
ING section.
2. Push in and turn
bulb counterclock
wise, then pull out
to remove.
3. Push in and turn
bulb clockwise, to
. replace. Bulb must
not be higher than
15 Watts(130 Volts).
4. Reinstall Power-Mate® cover as shown in
BELT CHANGING AND AGITATOR CLEAN
ING section.
NOTE:
See PARTS AND FEATURES for
bulb number.
IN
A
WARNING
Electrical Shock Or Personal Injury
Hazard
Disconnect electrical supply before
servicing or cleaning the unit.
Failure to do so could result in elec
trical shock or personal injury from
cleaner suddenly starting.
TO CHECK AGITATOR
ASSEMBLY
Base Support Bars
When brushes
are worn to the
level of the base
support bars,
replace the
agitator
assembly.
TO REPLACE AGITATOR
ASSEMBLY
1. Remove Power-Mate® cover, belt and
agitator assembly. See "To Remove Belf
in BELT CHANGING AND AGITATOR
CLEANING.
2. Replace Agitator
3. Replace belt, agitator assembly, Power
Mate* cover, light bulb and light cover.
See ‘To replace belf in BELT CHANGING
AND AGITATOR CLEANING.
18