Electrical shock or personal injury hazard, Warning – Kenmore 11 User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Always follow all safety precautions when
cleaning and servicing the Power-Mate®.
WARNING
Electrical Shock Or Personal Injury
Hazard
Disconnect electrical supply before
servicing or cleaning the unit
Failure to do so could result in elec
trical shock or personal injury from
cleaner suddenly starting.
TO REMOVE BELT
I.Turn Power
Mate® upside
down.
2. Unscrew the
two (2) Power
Mate® cover
screws.
3. Turn Power
Mate® right side
up. Press handle
release pedal
and lower the
swivel. Lift rear
latches up.
Side
Latch
Rear
Latches
4. To remove cover,
grasp the sides and
pull out.
5. Lift agitator
assembly out
and remove
worn belt.
End Cap
6. Check and clean end cap areas. See
AGITATOR ASSEMBLY for picture of
complete agitator assembly.