Safety Precautions
AWARNING
The water heater with draft hood installed must be prop
erly
vented
to
a
chimney
which
terminates
outdoors.
Never operate the water heater unless it is vented to the
outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphjmiation.
AWARNING
Minimum clearances between the water heater and com
bustible construction are I” at the sides and rear, 4" at the
front, and 6" from the vent pipe. Clearance from the top
of the jactwt is 18" on most models. Note that a lesser
dimension may be allowed on some models. Refer to the
label on the water heater adjacent to the gas control valve
for all clearances.
ACAUTION
WATER
HEATERS
EVENTUALLY
LEAK:
Installation
of
the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow
of water will not cause damage to the structure. For this
reason, it Is not advisable to install the water heater in an
attic
or
upper
floor.
When
such
locations
cannot
be
avoided, a suitable drain pan should be installed under
the water heater. Drain pans are available at your local
Sears store. Such a drain pan must be not greater than
11/2 inches deep, have a minimum length and width of at
least 2 inches greater than the water heater dimensions
and must be piped to an adequate drain. The pan must
not restrict combustion air flow. Under no circumstances
is the manufacturer or Sears to be held liable for any
water damage in connection with this water heater.
AWARNING
Do not use this appliance if any part of it has been under
water.
Immediately
call
a
Sears
Service
Technician
to
in^Kct the appliance and to replace the gas control or any
part of the burner system which has been under water.
AWARNING
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of
time
(generally
two
weeks
or
more).
Hydrogen
gas
is
extremely flammable and explosive. To prevent the possi
bility of injury under these conditions, we recommend the
hot water faucet be opened for several minutes at the
kitchen
sink
before
any
electrical
appliances
which
are
connected to the hot water system are used (such as a
dishwasher or washing machine). If hydrogen gas is pre
sent, there will probably be an unusual sound similar to air
escaping
through
the
pipe
as
the
hot
water
faucet
is
opened. There must be no smoldng or open flame near
the faucet at the time it is open.
AWARNING
INSULATING JACKETS: When installing an external
water heater insulation jacket on a gas water heater:
• DO NOT cover the temperature-pressure relief valve.
•
DO NOT put insulation over any part of the top of the
gas water heater.
• DO NOT put insulation over the gas control valve or gas
control valve/bumer cover, or any access areas to the
burner.
•
DO NOT let insulation around the gas water heater to
get within 8 inches of the floor (air must get to the
burner).
•
DO NOT cover or remove operating instructions, and
safety related warning labels and materials affixed to the
water heater.
Failure to heed this will result in the possibility of a fire or
explosion.