Service and Adjustment (cont’d)
L.R Gas Control Valve & Burner
Assembly Replacement
Information
AWARNING
PROPANE
(LR)
GAS
CONTROL
VALVE
AND
BURNER
ASSEMBLY REPLACEMENT INFORMATION.
For Propane (LR) Gas Models Only;
Your heater is equipped with a Propane (LR) gas
ohi
-
troljralve and a main burner assembly with left hand threads
for the following fittings and thdr connections.
•
The connection between the manifold and the gas
control valve (A to B) are left hand threads.
•
The connection between the main burner orifice
and the manifold (C to D) are left hand threads.
For
ordering
these
replacement
parts,
please
refer
to
the “Repair Parts” section of this manual.
Draining
The ^ter heater should be drained if being shut down during
frMzing temperatures. Also periodic draining and cleaning of
sediment from the tank may be necessary.
• Turn the gas control knob to the “OFF” position.
• CLOSE the cold water inlet valve to the water heater.
•
* nearby hot water iaucet and leave open to allow for
draining.
• Connect a hose to the drain valve and terminate to an ade
quate drain.
• OPEN the water heater drain valve to allow for tank
draining.
Heater is goii^ to be shut down and
drained for an extended period^ the drain valve should be
left open with hose connected allowing water to terminate
to an adequate drain.
• Close the drain valve.
• Follow instructions in the “Filling Jhc Water Heater”
sfection.
'
• Follow the lighting instructions in the “Lighting” section to
restart the water heater.
Temperature-Pressure
Relief
Valve Operation
The temperature-pressure relief valve must be manually operated
at least once a year.
^
TEMPERATURE-PRESSURE
RELIEF VALVE
DISCHARGE PIPE
Failure to install and maintain a new properly listed tempera
ture-premure relief valve will release the manufteturer from any
claim which might result from excessive temperature or pressure.
AWARNING
If
the
temperature-pressure
relief
valve
on
the
appliance
weeps or discharges periodically, this may be due to thermal
expansion.
Your
water
heater
may
have
a
check
valve
in^led in the water line or a water meter with a check
t«ive. Consult the Sears Service Center for further Informa
tion. Do not pli
4g the temperature-pressure relief valve.
AWARNING
When checking the temperature-pressure relief valve opera
tion, make sure that (!) no one is in front of or around the
ou^ of the temperature-pressure relief valve discharge line,
and (z) that the water maiiually discharged will not cause any
[wuperty damage because the water may be extremdy hot
If after manually operating the valve, it foils to completely
reset and continues to release water, immediately close the
cold water inlet to the water heater, follow the draining
instructions,
and
replace
the
temperature-pressure
relief
valve with a new one.