Installation Instructions (contad)
Installation Checklist
BEFORE LIGHTING THE PILOT;
• Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leab
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
c. Check for bubbling soap. This means you have a leak.
Turn “OFF” gas and make the necessary repairs.
d. Rcchcck for leaks,
e. Rinse off soapy solution and wipe dry.
•
Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See "Temperature-Pressure
Relief Valve” section.
•
Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions in the
“Installation Instructions” section,
•
Is the water heater completely filled with water? See “Filling”
instructions in the “Installation Instructions” section,
•
Will a water leak damage anything? Sec the “Facts to
Consider About the Location” section.
•
Is there proper clearance between the water heater and any
thing that might catch fire? See the “Facts to Consider About
the Location” section.
•
Do you have adequate ventilation so that the water heater
will operate properly? See “Combustion Air and Ventilation”
in the “Faas to Consider About the Location” section.
•
Is the draft hood vent piping properly secured? See “Venting”
instructions in the “Installation Instructions” section.
•
Is there proper clearance between the vent pipe and anything
that tnight catch on fire? See “Venting” instructions in the
Installation Instructions” section.
•
Is the vent pipejiroperly sloped and does the vent terminate
outdoors? See Venting” instructions in the “Installation
Instructions” section.
•
• Do you need to call your gas company to check the gas pipe
and its hookup?
VENT PIPE TO UNION
OUTDOORS
OR CHI MNEY
UTOFF VALVE
GAS SUPPLY
ifc| ^TEMPERATURE-
"
PRESSURE
RELIEF VALVE
DISCHARGE PIPE
(Do not cap or plug)
TEE -
DRIP LEG
(Sediment
trap)
DRAIN VALVE
PIPE CAP