Safety Precautions
▲WARNING
Improper
installation,
adjustment,
alteration,
service
or
maintenance
can
cause
DEATH,
SERIOUS
BODILY
INJURY,
OR
PROPERTY
DAMAGE.
Refer
to
this
manu-
ai
for
assistance
or
consult
your
local
Sears
Service
Center for further information.
▲WARNING
WATER
HEATERS
EQUIPPED
FOR
ONE
TYPE
GAS
ONLY; This water heater is equipped for one type gas
only. Check the model rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER
HEATER
WITH
ANY
GAS
OTHER
THAN
THE
ONE
SHOWN
ON
THE
MODEL
RATING
PLATE.
Failure
to
use the correct gas can cause problems which can result in
DEATH,
SERIOUS
BODILY
INJURY,
OR
PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.
▲WARNING
INSTALLATIONS
IN
AREAS
WHERE
FLAMMABLE
LIQ
UIDS
(VAPORS)
ARE
LIKELY
TO
BE
PRESENT
OR
STORED
(GARAGES,
STORAGE,
AND
UTILITY
AREAS,
ETC);
Flammable
liquids
(such
as
gasoline,
solvents,
propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as
property damage.
If installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline
and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
▲WARNING
If this water heater will be used in beauty shops, barber
shops,
cleaning
establishments,
or
self-service
laundries
with
dry
cleaning
equipment,
it
is
imperative
that
the
water heater or water heaters be installed so that com
bustion
and
ventilation
air
be
taken
from
outside
these
areas.
Refer
to
the
"Facts
to
Consider
About
the
Location" section of this manual and also the latest edi
tion
of
the
National
Fuel
Gas
Code,
ANSI
Z223.I,
also
referred to as NFPA 54 for specifics provided concerning
air required.
▲WARNING
A fire can start if combustible materials such as clothing,
cleaning
materials,
or
flammable
liquids
are
piaced
i^nst
or next to the water heater.
▲WARNING
At the time of manufacture this water heater was provid
ed
with
a
combination
temperature-pressures
relief
valve
certified
by
a
nationally
recognized
testing
laboratory
that
maintains
periodic
inspection
of
produrtion
of
listed
equipment
or
materials,
as
meeting
the
requirements
for Relief Valves and Automatic Gas Shutoff Devices for
Hot
Water
Supply
Systems,
and
the
latest
edition
of
ANSI
Z2I.22
and
the
code
requirements
of
ASME.
If
replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure
relief
valve
certified
as
meeting
the
require
ments
for
Relief
Valves
and
Automatic
Gas
Shutoff
Devices for Hot Water Supply Systems, ANSI Z21.22 by
a
nationally
recognized
testing
iaboratory
that
maintains
periodic
inspection
of
production
of
listed
equipment
or
materials.
The valve must be marked with a maximum set pressure
not
to
exceed
the
marked
hydrostatic
working
pressure
of
the
water
heater
(ISO
Ibs./sq.
in.)
and
a
discharge
capacity
not
less
than
the
water
heater
input
rate
as
shown
on
the
model
rating
plate.
(Electric
heaters
-
watts divided by 1000 x 3415 equal BTUAHr. rate.)
Your focal jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying
with ANSI Z2I.22 and ASME, may require a valve model
different from the one fomished with tiie water heater.
Compliance with such local requirements must be satis
fied by the installer or end user of the water heater with
a locally prescribed temperature-pressure relief valve
installed in the designated opening in the water heater in
place of the factory furnished valve.
For safe operation of the water heater, the relief valve
must
not
be
removed
from
it*s
designated
opening
or
plugged.
The
temperature-pressure
relief
valve
must
be
installed
directly
into
the
fitting
of
the
water
heater
designated
for the relief valve. Position the valve downward and pro
vide tubing so that any discharge will exit only within 6
inches
above,
or
at
any
distance
below
the
structural
floor. Be certain that no contact is made with any live
electrical
part.
The
discharge
opening
must
not
be
blocked
or
reduced
in
size
under
any
circumstances.
Excessive length, over 30 feet, or use of more than four
elbows
can
cause
restriction
and
reduce
the
discharge
capacity of the valve.
No valve or other obstruction is to be placed between
the
relief
valve
and
the
tank.
Do
not
connect
tubing
directly to discharge drain unless a 6" air gap is provided,
lb prevent bodily injury, hazard to life, or property dam
age, the relief valve must be allowed to discharge water
in
quantities
should
circumstances
demand.
If
the
dis
chaise pipe is not connected to a drain or other suitable
means, the water flow may cause property damage.
The Discharge Pipe:
*
Must not be smaller in size than the outlet pipe size of
the
valve,
or
have
any
reducing
couplings
or
other
restrictions.
• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
*
Must be installed so as to allow complete drainage of
both
the
temperature-pressure
relief
valve,
and
the
discharge pipe.
• Must terminate at an adequate drain.
*
Must not have any valve between the relief valve and