Warning, When to look for spiders – Kenmore 122.161249 User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
'! ■ WARNING
Spiders and insects can nest inside the burners of the grill and disrupt gas flow. This very dangerous
condition could cause a fire behind the valve panel, thereby damaging the grill and making it unsafe for
operation. Inspect the grill at least twice a year.
When to Look for Spiders
You should inspect the burners at ieast twice a year or immediately after any of the
following conditions occur:
1.
The
2.
The
3.
The
4.
The
5.
See
TROUBLE SHOOTING
BEFORE CALLING FOR SERVICE
Problems
What To Do
Grill will not light.
•Check to see if the liquid propane cylinder is empty.
•Check burner ports for any blockage. Use a soft
wire brush to clear plugged ports.
•Check the gas orifice on the burner for an
obstruction. If orifice is blocked, clean with a needle
or thin wire. NEVER USE A WOODEN
TOOTHPICK.
Burner flame is yellow or orange in conjunction with
gas odor.
•Check for spiders and insects
•Call customer service at 1-800-913-8889
Low heat with the control knob on the “HI” setting.
•Make sure the grill area is clear of dust.
•Make sure the burner and orifice are clean.
•Check for spiders and insects.
•Is there adequate gas supply available?
•Is the grill being preheated for 15 minutes?
11