REECESSED
area
/
closet
INSTALLATION INSTRUCTIONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
Confined or Recessed Area Installation
Exhausting the dryer outside is recom
mended. The moisture and lint indoors
may cause:
• Lint to gather inside and around the
dryer and be a fuel for a fire.
• Moisture damage to woodwork, furni
ture, paint, wallpaper, carpet, etc.
• Housecleaning problems and possible
health problems.
Recessed installation that is not
exhausted outside must use Exhaust
Deflector Kit Part No. 3391278. This
kit is available at your local Sears store
or Sears Service Center.
Closet Installation
WARNING: To reduce the risk of fire,
this appliance must be exhausted
outdoors when installed in a closet.
NOTE: No fuel burning appliances
may be installed in the same closet
as a dryer.
PRODUCT DIMENSIONS
Location must be large enough to fully
open dryer door.
MINIMUM INSTAUATION SPACING. Closet installation MUST be exhausted outside.
- AdiSl cleaves tor wall, door and lloor moldings may be required. IT clearance
is acceptable but not recommended.
. . . . .
1
..,
•* Opening is minimum
ior
closet door. Louvered door with equivalent air
••• Etional spSeSee'ded when external exhaust elbow is used. Can be 0" clearance
when house exhausting is lined up directly with dryer exhaust.
The installation spacing is in inches
and is the minimum allowable.
* Additional spacing should be
considered for ease of installation
and,servicing.
• If closet door is installed, the
minimum air openings in top and
bottom are required. Louvered doors
with equivalent air openings in top
and bottom are acceptable.
> Closet installation must be exhausted
outside. Other installations must use at
least the minimum dimensions indicated.