beautypg.com

Motor protection system, Motor protector, Thermal protector – Kenmore 116.34924 User Manual

Page 12: Agitator motor overload protector, Performance indicator

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

MOTOR PROTECTION SYSTEM

Motor Protector
This vacuum cleaner has a motor

protector by-pass valve which

automatically opens to provide cooling air
to the vacuum cleaner motor when a clog

prevents the normal flow of air to the
motor. If the by-pass valve opens to
prevent motor overheating and possible
damage to the vacuum cleaner, you will
notice a change of sound as air rushes
through the valve opening.

To correct problem: See the TROUBLE­
SHOOTING
table and page 11.

NOTE: The motor protector may open

when using attachments

or when cleaning new
carpet, due to reduced
airflow caused by the
attachments themselves
or by new carpet lint filling
the bag quickly. See the
TROUBLESHOOTING
section.

Note: Do not block motor
protector.

Motor

Protector

Thermal Protector
This vacuum cleaner has a thermal

protector, which automatically trips to
protect both the vacuum cleaner and the

agitator motor from overheating. If a clog

prevents the normal flow of air to the
motor, the thermal protector turns the
motor off automatically. This allows the
motor to cool in order to prevent possible
damage to the vacuum cleaner.

To correct problem: Turn the vacuum

cleaner off and unplug the power cord
from the outlet to allow the vacuum
cleaner to cool and the thermal protector

to reset. Check for and remove clogs, if

necessary. Also check and replace any
clogged filters. Wait approximately

thirty (30) minutes and plug the

vacuum cleaner in and turn back on to
see if the motor protector has reset.

AGITATOR MOTOR

OVERLOAD PROTECTOR

The agitator motor has
built-in protection
against motor damage
should the agitator
jam. If the agitator

slows down or stops,

the agitator overload

protector shuts off the
agitator motor. The
vacuum cleaner motor
will continue to run.

Agitator Overioad

Protector

Reset Button

To correct problem: Turn off and unplug
vacuum cleaner, remove obstruction, then

press overload protector reset button.

If the problem persists, have the

vacuum cleaner serviced by a Sears or

other qualified service agent.

PERFORMANCE INDICATOR

When the unit is running with normal air
flow, the light on the performance indicator
is off. The light comes on whenever the
airflow becomes blocked. If that occurs,
check the disposable dust bag, motor
safety filter and other possible clog
locations shown in CLOG REMOVAL,

To correct problem: See the TROUBLE­
SHOOTING
table.

Note: The light

may also come

on when using
attachments,
due to reduced
airflow through
the attachment.

12

This manual is related to the following products: