beautypg.com

Style 2: direct wire strain relief, Electrical connection options if your home has, And you will be connecting to – Kenmore ELITE OASIS 110.6707 User Manual

Page 9: Go to section, Wire connection: power supply cord

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Put power supply cord through the strain relief. Be sure that

the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tighf fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any screws

from a %" (1.9 cm) UL listed strain relief (UL marking on strain
relief). Put the threaded section of the strain relief through the
hole below the terminal block opening. Reaching Inside the
terminal block opening, screw the removable conduit
connector onto the strain relief threads.

A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads

Put direct wire cable through the strain relief. The strain relief
should have a tight fit with the dryer cabinet and be in a
horizontal position. Tighten strain relief screw against the
direct wire cable.

Electrical Connection Options

If your home has;

4-wire receptacle
{NEMAtype 14-30R)

( D D ]

And you will be
connecting to:

A UL listed,

120/240-volt

minimum,
30-amp, dryer
power supply
cord*

Go to Section:

4-wire connection;

Power Supply
Cord

4-wire direct

A fused

4-wire connection;

disconnect or

Direct Wire

circuit breaker
box*

(12.7 cm)

3-wire receptacle
{NEMAtype 10-30R)

A UL listed,

120/240-volt

minimum,
30-amp, dryer
power supply
cord*

3-wire connection:

Power Supply
Cord

3-wire direct

I

---3V4’—I

(8.9 cm)

A fused
disconnect or
circuit breaker
box*

3-wire connection;

Direct Wire

*lf local codes do not permit the connection of a cabinet-ground

conductor to the neutral wire, go to “Optional 3-wire
connection” section.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.

C ^

E

A. 4-wire receptacle (NEMA type 14-30R)

B. 4-prong plug

C. Ground prong
D. Neutral prong

E. Spade terminals with upturned ends
F. %" (1.9 cm) UL listed strain relief

G. Ring terminals

4. Now complete installation following instructions for your type

of electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)