Electrical Connection
Power Supply Cord
Direct Wire
M
M
Fire Hazard
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use 10 gauge solid copper wire.
Use a UL listed strain reiief.
Use a UL listed strain reiief.
Disconnect power before making electrical connections.
Disconnect power before making electrical connections.
Connect neutrai wire (white or center wire) to center
Connect neutral wire (white or center wire) to center
terminal (silver).
terminal (silver).
Ground wire (green or bare wire) must be connected to
Ground wire (green or bare wire) must be connected to
green ground connector.
green ground connector.
Connect remaining 2 supply wires to remaining
Connect remaining 2 supply wires to remaining
2 terminals (gold).
2 terminals (gold).
Securely tighten all electrical connections.
Securely tighten all electrical connections.
Failure to do so can result In death, fire, or
Failure to do so can result in death, fire, or
electrical shock.
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
/A B
C D
E
F
A. Terminal block cover
B. Hold-down screw
C. External ground conductor screw
D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Hole below terminal block opening
3. Install strain relief.
Style 1: Power supply cord strain relief
■ Remove the screws from a %" {1.9 cm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down,
and hold In place. Tighten strain relief screws just enough to
hold the two clamp sections together.
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down