Warning

: Before starting any work ensure

that all sources of power are turned off. All

work must meet local/national codes and be
performed by a certified electrician. Do not

mount fixtures vertically.

Installation Instructions

Vault w/ visor

C-Scroll w/ visor

Roundel w/ visor

These installation instructions are valid with the above Ametrix styles.

4.

5.

Sheet 3 of 4

Small, INDOOR

SRR

(Semi-Recessed, Remote ballast)

Visor and Non-Visor

ADY071459 REV B (ECN80481)

Semi-recessed fixtures shown without thermal protectors

Securing the fixtures with safety wire

(both ceiling grid and drywall)

1. If applicable, replace ceiling tile with fixture secured back into ceiling. Remove adjacent tile from ceiling to facilitate wiring.
2. Depending on location of power source, loosen #10-32 x3/8" Pan head screws and remove appropriate cover plate and
knock out appropriate hole.
3. Using conduit fitting and washer, secure conduit to cover plate.
4. Attach appropriate wires and ensure all connections are properly matched.
5. Replace cover plate and secure with #10-32 x3/8" Pan head screws.

Choose appropriate cover plate
depending on location of power
source.

Ceiling surface

#10-32 x3/8"
Pan head screw
(2x)

Wiring the fixture

(both ceiling grid and drywall)

1. After securing fixture housing to ceiling structure using provided brackets, reinforce fixture using safety wire(by others).
2. Using all four tabs located on corners of fixture housing, tie off fixture to structure using safety wire(by others).

Cover plate

Conduit
(by others)

Conduit fitting
(by others)

Conduit Nut
(by others)

Safety wire
(by others)

Fixture housing