- STEP 6: SANITIZING, PRESSURE TESTING & PURGING -
SANITIZING
Sanitizing is recommended upon installation of the
RO system^ and after servicing inner parts.
It is im
portant for the service person to have clean hands
while handling inner parts of the system.
CAUTION: Be sure to remove the RO membrane
and both filter cartridges as follows, before sanitiz
ing. Chlorine will destroy the RO membrane car
tridge.
1.
Be sure the
water supply to the RO is turned off,
and the
RO faucet is open
to relieve pressure.
2. Referring to FIG, 9, page 12, remove the RO mem
brane sump by twisting 1/4 turn left (O). Remove
the RO cartridge from sump. Place the cartridge in
a
clean
plastic bag.
3. Be sure the o-ring seal is on the sump. Replace the
RO sump by turning to the right (U) to lock.
4.
Remove the postfilter sump, turning to the left.
Take the cartridge from the sump and place in the
plastic bag. Replace the sump by turning to the right
(U) to lock.
5. Remove the prefilter sump and cartridge. Also
place this cartridge in the clean bag.
6. If needed to clean, flush the prefilter sump with
fresh water. Then fill with water to about 1" from the
top. Add 1.0 ounce of chlorine (ordinary 5.25%
household bleach,.. Hilex, Clorox, etc,) and mix in the
water.
Do not add chlorine first.
Concentrated it will
attack plastics.
7. Carefully replace the sump on the prefilter head
and turn to the right (U) to lock.
8. Slowly open the water supply to the RO,
9.
Open the RO faucet by turning knob to the left.
10.
Allow water to circulate through the RO system
until you smell the bleach odor at the faucet. Then
close the faucet and allow the RO to stand idle for 20
minutes.
11.
After the 20 minutes open the RO faucet and run
water until the bleach odor is gone.
12. Turn off the water supply to the RO.
13.
Be sure your hands are clean. Then, repeat steps
1 - 5
and
7,
only
replace all cartridges.
Important: Refer to FIG. 9, page 12, and to page 13
when replacing cartridges. The prefilter (left side)
cartridge and the postfilter (right side) have puple
end caps.
PRESSURE TESTING
1. Do the preceding sanitizing procedures before
pressure testing.
2. Open the water supply shutoff valve to the RO.
3. Open the
main
water supply valve and several
house faucets to purge air from the system. Close
faucets when water runs smooth.
4. In about 2 hours, pressure will start to build in the
RO system.
Then,
carefully check all fittings and con
nections for water leaks. Correct leaks if any are
found.
Note: When the system is first pressurized, water
may "spurt" from the faucet airgap hole until air is
expelled from the RO system.
PURGING RO MEMBRANE
Important purging instructions: The RO cartridge
contains a food grade preservative that should be re
moved before using water from the system. The pre
servative will give product water an unpleasant taste
and odor.
1. Allow the storage tank to fill for about 4 hours.
Then open the RO faucet until the tank is empty and
flow stops.
2. Close the RO faucet and allow the tank to fill again
for 4 hours. Then open the RO faucet and empty
again.
Repeat steps 1 and 2 to purge the storage tank 6 times. Then the RO system is ready to
make product water for use.
Problems, Questions? Call 1 -800-426-9345 Kenmore Water Une