Dimensions and specifications – Kenmore ULTRAFILTER 300 625.384720 User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
DIMENSIONS and SPECIFICATIONS
15”
Supply water pressure limits ................................................ 40 - 100 psi
Supply water temperature limits............................................ 40 - 100 °F
Maximum total dissolved solids (IDS) .................................. 2000 ppm
Maximum water hardness @ 6.9 pH .................... ............... 10 gpg
Maximum iron, manganese, hydrogen sulfide...................... 0
Chlorine in water supply (max. ppm) .................................... 2.0
Supply water pH limits (pH) ..... ............................................ 4 - 1 0
Product (quality) water, 24 hours
CD ..................................... 12 gal.
Waste water per gallon of product water Q).......................... 5 gal.
Percent rejection of TDS, minimum (new membrane) ®
80 - 95
Storage tank capacity (max.) ................................................ 2.3 gal.
Automatic shutoff control....................................................... yes
Metric
280 - 690 kPa
5 - 40°C
45.42 liters
18.9 liters
8.7 liters
CD
feed water supply at 50 psi,
77'
F, and 750 TDS - Quality water production, amount of waste
water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.
Problems, Questions? Call 1
16
■800-426-
■9345 Kenmore Water Line