5b make electrical connections, Installation instructions – GE JD750SFSS User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Installation Instructions
5B MAKE ELECTRICAL CONNECTIONS
Place the unit on a platform or table even with the cutout opening. The platform must support 200 lbs. (91 kg).
Connect the flexible conduit to the electricaljunction box os follows:
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads or ground are aluminum conductors, see WARNING in section 5A, Electrical
Requirements.
When connecting to a three-conductor branch circuit, if local codes permit:
1. Connect the bare oven ground conductor with the
crimped neutral (white) lead to the branch circuit
neutral (white or gray in color), using wire nuts.
2. Connect the oven red lead to the branch circuit red
lead, and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts.
Black
Range conduit
snaps into box
3. Install proper strain relief clamp.
4. Installjunction box cover.
Red
Ground and
neutral wires
(white)
Alternate
knockout
Neutral bore wire
connection
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads or ground are aluminum conductors, see WARNING in section 5A, Electrical
Requirements.
When connecting to a four-conductor branch circuit, if local codes permit:
1. Cut the neutral (white) lead from the clamp. Re-strip
the neutral (white) lead to expose the proper length
of conductor.
Black
2. Attach the appliance grounding lead (green or bare
copper) in accordance with local codes.
3. Connect the oven neutral (white) lead to the branch
circuit neutral (white or gray) in accordance with
local codes, using a wire nut.
4. Connect the oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts.
5. Install proper strain relief clamp.
6. Installjunction box cover.
Range conduit
snaps into box
Branch
circuit
Alternate
knockout
White