This product has been tested and listed by NSF International under Standard 42

® ] for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class

II) and under Standard 53 for Cyst, Turbidity, Lead and VOC reduction.

Whirlpool Water Filtration System

SPECIFICATIONS: Lead, VOC and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons

SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psi ^

Performance Data Sheet

Systems I, II &

General

Performance

Average

Influent

Maximum

Effluent

Mlnlmum%

Reduction

NSF Test

Requirement

Chlorine'

2.0 mg/L

<0.1 mg/L

92%

minimum75%

reduction (Clas^ 1)

Particulate

560,000 part/mL^ 18,000 part/mL

98%

minimlim 85%

reduction (Class II)

Cyst

215,000 4-6n/mL3 390 4-6 ti/mL

99.9%

minimum 99.9%

reduction

Turbidity

14NTU

0.42 NTU

97%

minimum effluent

1.0 NTU

Contaminant

Reduction

Performance"

U.S. EPA

MCL

Average

infiuent

Maximum

Effluent

Minimum%

Reduction

NSF Test

Requirement

Lead @ pH 6.50.015 mg/L 0.16 mg/L5 0.005 mg/L

97%

maximum effluent

0.015 mg/L

Lead @ pH 6.5 0.015 mg/L 0.17 mg/L® 0.002 mg/L

99%

maximum effluent

0.015 mg/L

'Free Available Chlorine.

^est requirement is at least 10,000 Partides/mL of AC Fine Test Dust.
^esl requirement is 4-6 micrometer size particles per mL of influent.
^These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

^Tes

1

requirement 0.15 mg/L± 15%.

VOLATILE ORGANIC CHEMICAL REDUCTION

This system has met the testing requirements of Standard 53, Section 5.1.1 for the

reduction of chloroform, which is the surrogate for the foliowing chemicals

Maximum

Influent

Minimum

Occurrence

Effluent

Concentration Percent

Chemical Levels (ppb)

Level (ppb) Other VOC’s’

(ppb)

Reduction

Benzene 30'

cis-1,3-Dichloropropene 80

95%

Carbon Tetrachloride 40'

Chlorobenzene

80

95%

p-Dichlorobenzene 80®

5"

Hexachlorobutadiene

40

95%

Trichloroethylene 300'

ortho-Xylene

80

95%

Trihalomethanes 300

15

trans-1,2-Dichloroethene 80

95%

(surrogate chemical)

1,1,2,2-Tetrachloroethane80

95%

1,1 -Dichloroethylene 50'

1,2-Dichlorobenzene

80

95%

1,1,1 -T richloroethane 80®

5"

1,2-Dichloroethane

80

95%

1,2-Dichloroethane 100'

Ethylbenzene 80®

4"

Tetrachloroethylene 80®

4"

Toluene 80®

4"

1,2-Dichloropropane 80®

'Influent levels are the 95th percentile, cxxurrence levels are per Federal Register, Vol. 50, No. 219, November 13,1965, p

46917.

^Since the 95th percentile occurrence levels were too low and thus were not pertinent for testing these chemicals against their MCL’s,

a reasonable level was selected for surrogate testing as shown.

^EPA Primary Maximum Contaminant Levels
^Maximum effluent concentrations set at the practical quantitation level (POL) which is less than the MCL.
^In the absence of officially stated occurrence levels and MCL’s, the surrogate influents were selected to provide a reasonable test.

APPLICATION GUIDELINES/WATER SUPPLY PARAMETERS

Water supply - community or private well

Potable (suitable for drinking)

Water Pressure

30-100 psi (207 - 690kPa)

Water Temperature

40° - 100°F (4.4° - 38°C)

pH Range

6-9

Maximum TDS Level

500 ppm

Dissolved Iron

< 0.1 ppm

Dissolved Manganese

< 0.05 ppm

Turbidity

< 1 NTU

Water supplies that exceed limits for iron or manganese require (xetreatment.

It is essential that operational, maintenance and filter replacement requirements be carried out for the product to perform
as adv^ised.

CAUTION: Do Not use where water is microbiologically unsafe or wKh water of unknown quality without adequate
disinfection before or after the unit.

WARRANTY

Length of Warranty:

Whirlpool will pay for:

One Year Full Warranty
(From date of purchase)

Replacement parts and repair labor to correct defects
in materiais or workmanship for the entire product
except for the filter cartridge(s). Service must be
provided by an authorized Whirlpool servicing outlet.

Five Year Limited Warranty
(Second through fifth year
from date of purchase)

Replacement parts to correct defects in materials or

workmanship for the entire product except for the
filter cartridge(s).

Whirlpool will not pay for:

A. Service calls to:

1.

) Correct the installation of the product. System must be installed and operated in accor­

dance with Whirlpool procedures and guidelines.

2.

) Instruct you how to use the product.

3.

) Correct house plumbing.

B. Repairs when product is used in other than normal, single-family household use.
C. Repairs when product Is damaged from neglect, misuse, abuse, freezing or hot water, fouling

with sediment or scale, bacterial attack, alterations, improper installation, or installation not in
accordance with local plumbing codes.

D. Any labor costs during the limited warranty.
E. Replacement parts or repair labor costs for units operated outside the U.S.
F. Pickup and delivery. This product is designed to be repaired in the home.
G. Repairs to parts or systems caused by unauthorized modifications made to the product.

The performance and functioning of your water filtration system is directly related to the quality of
the water being treated and the particular application in which it Is used. Please consult "Water

Requirements” and “Use & Care”.

Whiripool shall not be liable for Incidental or consequential damages. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may

not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.

13

This manual is related to the following products: