This product has been tested and listed by NSF International under
Standard 42 for Taste, Odor and Chlorine reduction (Class I) and

Particulate reduction (Class II).

Performance Data Sheet

Whirlpool Water Filtration System I

Model No. WSC100YW

SPECIFICATIONS: Taste/Odor/Chlorine reduction (Class I) CAPACITY: 1,000 Gallons

SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psi

General

Performance

Average

Influent

Maximum

Effluent

Minimum%

Reduction

NSF Test

Requirement

Chlorine'

2.0 mg/L

<0.1 mg/L

92%

minimum 75%

reduction (Class 1)

Particulate

560,000 part/mL^ 18,000 part/mL

98%

minimum 85%

reduction (Class II)

Performance may very based on local water conditions.
^Free Available Chlorine.
n'est requirement is at least 10,000 particles/mL of AC Fine Test Dust.

This product has been tested and listed by NSF International under Standard 42

®) for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class

II) and under Standard 53 for Cyst, Turbidity and Lead reduction.

Whirlpool Water Filtration System II

Model No. WSC200YW

SPECIFICATIONS: Lead and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons

SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psI

General

Performance

Average

Influent

Maximum

Effiuent

Minimum%

Reduction

NSF Test

Requirement

Chlorine’

2.0 mg/L

<0.1 mg/L

92%

minimum75%

reduction (Class 1)

Particulate

560,000 part/mL^ 18,000 part/mL

98%

minimum 85%

reduction (Class II)

Cyst

215,000 4-6 n/mL3 390 4-6 p/mL

99.9%

minimum 99.9%

reduction

Turbidity

14NTU

0.42 NTU

97%

minimum effluent

1.0 NTU

Contaminant

Reduction

Performance^

U.S. EPA

MCL

Average

influent

Maximum

Effluent

Minimum%

Reduction

NSF Test

Requirement

Lead @ pH 6.5 0.015 mg/L 0.16 mg/L^ 0.005 mg/L

97%

maximum effluent

0.015 mg/L

Lead @ pH 8.5 0.015 mg/L 0.17 mg/mL®0.002 mg/L

99%

maximum effluent

0.015 mg/L

^Free Available Chlorine.
H'est requirement is at least 10,000 partides/mL of AC Fine Test Dust.
^est requirement is 4-6 micrometer size partides per mL of influent.
^These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

®Test requirement 0.15 mg/L± 15%.