3. Positive Displacement (PD) Pump - Following is a list of possible Symptoms and
Troubleshooting Solutions.
Symptom
Possible Causes
Possible Sources
Noisiness
Rotor-to-Rotor
Contact
Rust Build up or Rotors
Rotors Out of Time
Excessive Pressure Ratio
Failed Bearings (s)
Failed Gears
Failing Bearing (s)
Faulty Installation
Non-spec Oil
Contaminated Oil
Insufficient Oil
Improperly Mounted Sheave
Over-tightened Belts
Failing Gears
Insufficient Backlash
Non-spec Oil
Contaminated Oil
Insufficient Oil
Sever Torsional Vibration
Failing Lubricated
Coupling or Joint
Non-spec Grease
Contaminated Grease
Insufficient Grease
Loose Attached
Hardware
Belt Guard
Pump Mounting Bracket
Frame Members
In/Out Piping Supports
Air Leakage
Improper Relief Valve Setting
Blown Gaskets
Loose Piping Joints
Belt Flutter
Insufficient Static Tension
Sheave Misalignment
Sever Torsional Vibration