beautypg.com

Troubleshooting – Chicago Electric MULTI-FUNCTION POWER TOOL 67256 User Manual

Page 12

background image

SKU 67256

For technical questions, please call 1-800-444-3353.

Page 12

Troubleshooting

Problem

Possible Causes

Likely Solutions

Tool will not start.

Cord not connected.

1.

No power at outlet.

2.

Internal damage or wear.

3.

(Carbon brushes or switch,

for example.)

Check that cord is plugged in.

1.

Check power at outlet. If outlet is unpowered,

2.

turn off tool and check circuit breaker. If

breaker is tripped, make sure circuit is right

capacity for tool and circuit has no other

loads.
Have technician service tool.

3.

Attachment is loose

on the tool.

Holes on attachment not

1.

lined up with pins on Spindle.

Cap screw not tight enough.

2.

Remove the attachment and re-mount,

1.

making sure that the holes in the attachment

are secured over the pins on the Spindle.
Remove the attachment and re-mount,

2.

making sure that the holes in the attachment

are secured over the pins on the Spindle,

then tighten the Cap Screw to at least 10

ft-lbs.

Tool operates slowly. Extension cord too long or wire

size too small.

Eliminate use of extension cord. If an extension

cord is needed, use shorter/heavier gauge cord.

See Extension Cords in GROUNDING section.

Performance

decreases over time.

Attachment dull or damaged.

1.

Carbon brushes worn or

2.

damaged.

Keep cutting accessories sharp. Replace as

1.

needed.
Have qualified technician replace brushes.

2.

Excessive noise or

rattling.

Internal damage or wear.

(Carbon brushes or bearings,

for example.)

Have technician service tool.

Overheating.

Forcing tool to work too fast.

1.

Attachment dull or damaged.

2.

Blocked motor housing

3.

vents.

Motor being strained by long

4.

or small diameter extension

cord.

Allow tool to work at its own rate.

1.

Keep cutting accessories sharp. Replace as

2.

needed.
Wear ANSI-approved safety goggles and

3.

NIOSH-approved dust mask/respirator while

blowing dust out of motor using compressed

air.
Eliminate use of extension cord. If an

4.

extension cord is needed, use one with the

proper diameter for its length and load. See

Extension Cords in GROUNDING section.

Follow all safety precautions whenever diagnosing or servicing the

tool. disconnect power supply before service.

REV 10e