beautypg.com

Combustion area and vent system, Caution, Danger – Carrier WEATHERMAKER INFINITY 58MCA User Manual

Page 8

background image

8

to dry.

6. Reinstall clean air filter
7. Reinstall filter retainer (for blower compartment locations

only)

8. Replace blower access panel and main furnace door (see Fig.

30 and 31) or filter cabinet door (Fig. 32 and 33.)

9. Turn on electrical supply to furnace. If your furnace air filter

needs to be replaced, be sure to use a factory-authorized filter
of the same size that was orginally supplied. Use the filter
tables and compare your furnace size with the proper filter
size.

28

29

30

31

32

33

* Factory-provided with the furnace. Filters may be field modified by cutting-

filter material and support rods (3) in filters. Alternate sizes and additional
filters may be ordered from your dealer.

Upflow only.

COMBUSTION AREA AND VENT
SYSTEM

Visually inspect the combustion are and vent system before
each heating season. Make sure that all PVC pipes leading
into the combustion area and vent are free from any cracks
and sags. Check the combustion-air intake and vent pipe on
the outside of your home for blockage.
When dirt, soot, scale, or rust is allowed to build up, your
furnace can suffer a loss of efficiency and perform improper-
ly. Accumulations on the main burners can result in firing out
of normal sequence. This delayed ignition creates an alarm-
ingly loud sound.

To inspect the combustion area and vent system, you will
need a flashlight. Refer to Fig. 3 or 4, and proceed as follows:

1. Turn off the gas and electrical supplies to the furnace and

remove the main furnace door. (See Fig. 9, 10, and 11.)

2. Remove burner enclosure front. (See Fig. 34 or 35.)

Inspect the gas burners, ignitor area, and remainder of furnace
for dirt, rust, soot, or scale.

FURNACE AIR FILTER TABLE

AIR FILTER LOCATED IN BLOWER COMPARTMENT

FURNACE

CASING

WIDTH (IN.)

FILTER SIZE (IN)

FILTER

TYPE

Side Return

Bottom Return

17-1/2

(1) 16 x 25 x 1*

(1) 16 x 25 x 1*

Cleanable

21

(1) 16 x 25 x 1

(1) 20 x 25 x 1*

Cleanable

24-1/2

(1 or 2) 16 x 25 x 1 (1) 24 x 25 x 1*

Cleanable

AIR FILTER LOCATED IN FILTER CABINET

FILTER

CABINET

HEIGHT (IN)

FILTER

SIZE (IN)

FILTER

TYPE

16

(1) 16 x 25 x 1*

or (1) 16 x 25 x 4-5/16

Cleanable or

Disposable

20

(1) 20 x 25 x 1*

or (1) 20 x 25 x 4-5/16

Cleanable or

Disposable

24

(1) 24 x 25 x 1*

or (1) 24 x 25 x 4-5/16

Cleanable or

Disposable

CAUTION

Use care when cutting support rods in filters to
protect against flying pieces and sharp rod ends.
Wear safety glasses, gloves, and appropriate pro-
tective clothing. Failure to follow this caution
could result in personal injury.

DANGER

If holes are found in the pipes or if any portion has
become disconnected, toxic fumes can escape
into your home. DO NOT OPERATE YOUR FUR-
NACE. Call your dealer for service.

CAUTION

If your furnace makes an especially loud noise
when the main burners light, shut down your fur-
nace and call your dealer.

CAUTION

If dirt, rust, soot, or scale accumulations are found,
call your dealer. Do not operate your furnace.

!

!

!

!