beautypg.com

Cabletron Systems 9E138-36b User Manual

Page 20

background image

Installing the Modules

2-8

See the

Cautions

at the end of this table.

Table 2-2. Function of DIP Switch

Switch

Function

Description

8

Clear

Password

1

When toggled, this switch clears user-entered
passwords stored in NVRAM and restores the
default passwords. Once reset you can use the
defaults or enter new passwords.

7

Clear

NVRAM

2

The module uses NVRAM to store user-
entered parameters such as IP addresses,
device name, etc. To reset these parameters to
the factory defaults, toggle this switch. Once
reset you can use the defaults or enter new
parameters, which are stored in NVRAM
when the module is powered down, and
remain there until the switch is toggled again.

6

Force BootP

Download

3

Toggling this switch after pulling the board out
of the SmartSwitch 9000 clears download
information from NVRAM and forces image
files to be downloaded from the station
configured to act as that module’s BootP server
(connected to the EPIM on the Environmental
Module).

5

Reserved

Off - Factory Use Only

4

Reserved

Off - Factory Use Only

3

Reserved

Off - Factory Use Only

2

Reserved

Off - Factory Use Only

1

Reserved

Off - Factory Use Only

1

Caution:

Do not toggle Switch 8 unless you intend to reset the user configured

passwords to their factory default settings.

2

Caution:

Do not toggle Switch 7 unless you intend to reset the user parameters

to the factory default settings.

3

Caution:

Do not toggle switch 6 unless a bootp server is connected to the EPIM

of the Environmental Module.

!

CAUTION

This manual is related to the following products: