Tc/link: ++digisign / ++inc commands, Tc/link: some pdf files converted as blank pages – Kofax Communication Server 9.2.0 User Manual
Page 23
Resolved Issues
Kofax Communication Server Release Notes
23
TC/LINK: Conversion of Corrupt PDF Leads to Link Failure
Conversion of a corrupt PDF file could lead to link failure. This issue has been resolved.
(SPR00113139)
TC/LINK: Some PDF Files Converted as Blank Pages
Due to a limitation in a third-party document conversion library, some PDFs could not be
converted. This issue has been resolved by the third-party vendor. (SPR00101991)
TC/LINK: ++DIGISIGN / ++INC Commands
The ++DIGISIGN and ++INC commands are now recognized, even if they are the only
content of a text block. (SPR00175763)
KCS Monitoring: License Check Generating Entries in Audit Log
When using audit logs for logon/logoff with KCS Monitoring, a periodic license check
generated an entry in the logs every four seconds. The license information can now be cached
for up to 24 hours. (SPR00105711)
To activate license caching:
1 Open Cockpit.xml from the folder
with a text
editor.
2 Edit the lines:
In the field CacheLicenseHours, specify how many hours to cache a license if a license
check succeeds.
In the field CacheNoLicenseHours, specify how many hours to wait before another check
if a license check fails.
Setting either value to zero disables license caching in that case.
3 Restart the KCS Monitoring services to make the changes effective.
For more information, see:
▪ KCS Monitoring Technical Manual, version 1.02.00 edition 7
Chapter Installation - Prerequisites - License
TC/Probe: Wrong Database Password Causes Run-Time Error
Having an incorrect password in the registry value HKLM\SOFTWARE\Wow6432Node
\TOPCALL\TCPROBE\DBPassword used to result in a runtime error in the Management
Console. This situation is now handled properly. (SPR00121517)