The measurement cycle is by default set to 60 seconds, and can be configured in the following registry

value

(but it cannot be set lower than to 60 seconds, each value lower than 60 seconds would be set back to 60

seconds !)

HKLM\Software\TOPCALL\TCOSS\PerfCounterCheckCycle

Following table provides an overview of Key Performance Indicators that are being checked, their default

threshold limits and corresponding event log IDs:

KPI thresholds (in ms)

Configuration
(HKLM\SW\TOPCALL\TCOSS\...)

EventLogID

Warning

Information

KPI

(1)

Default thresholds

Local Disk Write
Latency [ms]

Avg.

20

DiskLocalAvgAccessTime

16054

16060

Peak

2000

DiskLocalPeakAccessTime

-

16055

Remote Disk Write
Latency [ms]

Avg.

25

DiskRemoteAvgAccessTime

16056

16061

Peak

2000

DiskRemotePeakAccessTime

-

16057

RTT

prim-sec

Avg.

10

DiskAvgNetworkDelay

16058

16062

Peak

500

DiskPeakNetworkDelay

-

16059

RTT

ls1

RTT

FoIP

Avg.

300

NodeAvgRoundTripTime

16063

16065

Peak

1000

NodePeakRoundTripTime

-

16064

RTT

storage-media

Avg.

10

MediaServerAvgRoundTripTime

16066

16068

Peak

500

MediaServerPeakRoundTripTime

-

16067

(1) Please refer to the chapter Resource Estimation and Key Performance Indicators for detailed KPI

description

Each event log entry saves following additional information on the counter threshold violation:

1. Counter name and its value that violated its limit (average or peak)

2. In the case of average counter violation, the corresponding peak value of the same counter (and vice

versa)

3. Information in percent how many values exceeded the average and peak limits

4. Information on the limit values for both average and peak thresholds

5. The duration of the measurement cycle (default 60 seconds)

Note that it can happen during an idle period of TCOSS (e.g. no faxes being currently active) that the

measurement cycle indicated would be much longer that the configured value (e.g. 7000 seconds). This is

cause by the fact that counter verification is done only during regular TCOSS (disk) activity.

Example of the Warning event log written in the case of average counter threshold violation:

Avg.local disk write time 30 ms exceeded avg.limit, peak was 360 ms, 0 perc. values
exceeded peak limit (1000 ms), 53 perc. values exceeded avg.limit (25 ms) during
last 60 sec

Example of the Information event log written in the case above average counter does not exceed its limit

anymore:

Avg.local disk write time 19 ms is within avg.limit again, peak was 360 ms, 0 perc.
values exceeded peak limit (1000 ms), 53 perc. values exceeded avg.limit (25 ms)