6 | maintenance – GEA Bock F18 User Manual
Page 20
20
D
GB
F
E
96246-07.2014-DGbRu
6.1 Preparation
6.2 Work to be carried out
6| Maintenance
Accessories available can be found on the Internet at www.bock.de.
6.4 Accessories
WARNING
Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch lock.
To guarantee optimum operating safety and service life of the compressor,
we recommend perfor-
ming service and checking work at regular intervals of time:
Oil change:
-
In series plants produced in the factory not mandatory.
-
In field installations or operating in the application limit range, first oil change after approx.
100 - 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of old oil according to the regulations, observe national regulations.
Annual checks: Oil level, tightness, running noise, pressures, temperatures, function of auxiliary
devices such as a oil sump heater, pressure switch. Comply with the national regulations!
F18 / ...
2735
3235
Designation
Ref. No.
Ref. No.
Set gaskets
80904
80905
Valve plate kit
80894
80895
Kit piston / connecting rod
80890
80891
Kit capacity regulator LR12
80889
80879
Oil pump kit
80116
Kit shaft seal
80897
Oil SP 46, 1 liter
02279
Oil SE 55, 1 liter
02282
6.3 Spare parts recommendation
Only use genuine Bock spare parts!