3 | areas of application, Einsatzgrenzen hgx34 co, D gb f e – GEA Bock HGX46 CO2 T User Manual
Page 11: Evaporation temperature (°c) ∆t, Suction gas superheat (k) p, Suction pressure (bar) p, Lp = low pressure hp = high pressure, Compressor version sh, Evaporation temperatures < 5°c (40 bar) on request
![background image](/manuals/657488/11/background.png)
D
GB
F
E
11
96259-12.2014-DGb
t
o
Evaporation temperature (°C)
∆t
oh
Suction gas superheat (K)
p
o
Suction pressure (bar)
p
v
2
Discharge end pressure (bar)
Unlimited
application range
Fig. 7
Max. permissible operating
pressure (LP/HP)
1)
: 100/150 bar
1)
LP = Low pressure
HP = High pressure
10
20
30
50
50
40
90
80
120
Einsatzgrenzen HGX34 CO
2
T
100
70
60
40
p
o
(bar)
p
V2
(bar)
110
130
140
60
0
-10
-20
-30
-40
10
t
o
(°C)
20
64,3
70
25
?t = 10 K
Oh
10
20
30
50
50
40
90
80
120
100
70
60
40
p
o
(bar)
p
V2
(bar)
110
130
140
60
0
-10
-20
-30
-40
10
t
o
(°C)
20
64,3
70
25
?t = 10 K
Oh
10
20
30
50
50
40
90
80
120
100
70
60
40
p
o
(bar)
p
V2
(bar)
110
130
140
60
0
-10
-20
-30
-40
10
t
o
(°C)
20
64,3
70
25
?t = 10 K
Oh
Compressor version SH
3 | Areas of application
Evaporation temperatures < 5°C (40 bar) on request