beautypg.com

System a - 100, A-150, Indicators – Doepfer A-150 Dual VC Switch User Manual

Page 3: Doepfer

background image

doepfer

System A - 100

Dual VCS

A-150

3

3. Indicators

1

LED ... 2 LED

LEDs 1 and 2 serve as status indicators, to show
which of the two in / outputs " and § is at that moment
connected to the common out / input $.

4. In / Outputs

!

CV

Socket ! is the input for the digital control voltage,
whose level determines the switch state (see Fig. 1):

• CV low ( < ~3.6 V):

O/I ---- I/O 1

• CV high ( > ~3.6 V): O/I ---- I/O 2

If a high frequency control voltage is used for swit-
ching, audio frequency modulation results (see Fig. 4
on page 5).

Fig. 1: The A-150’s switching behaviour

"

I/O 1 • § I/O 2

These sockets are the in / outputs.

$

O/I

Socket $ is the common out / input. Depending on
the level of control voltage at input ! it’s connected to
socket " or § (see Fig.1).

CV

~ 3.6 V

O/I

I/O 1
I/O 2

O/I

I/O 1
I/O 2

O/I

I/O 1
I/O 2