beautypg.com

Doepfer A-103 18dB Low Pass User Manual

Page 4

background image

A-103 18dB Low Pass

System A - 100

doepfer

4

4. In / Outputs

! CV 1

Socket CV 1 is the filter’s standard voltage control
input
, and works on the 1V / octave rule, like the
VCOs.

If you patch a modulation source (eg LFO, ADSR) to
this input, the cut-off frequency of the filter will be
modulated by its voltage: ie., the sound color changes
according to the voltage put out by the modulator.

If you use the VCF as a sine wave oscillator, connect
the pitch CV into this socket. Do the same if you want
the filter’s cut-off frequency to track exactly with the
pitch of a note (filter tracking).

" CV 2 • § CV 3

Sockets CV 2 and CV 3 are also voltage control
inputs for the filter.
Unlike CV 1, you can control the
level of voltage - the intensity of modulation effect on the
filter - with attenuators

2 and 3.

$ Audio In

This is the filter’s audio input socket. Patch in the
output from any sound source (eg. VCO A-110/A-111,
Sampler/Wavetable Oscillator A-112, Subharmonic Ge-
nerator A-113, Ring Modulator A-114, Audio Divider
A-115, Waveform Processor/Waveshaper A-116/ A-136,
Noise Generator A-117/118, external audio signal e.g.
via A-119, VC Divider A-163, mixed signal of different
audio sources using A-138 and so on).

% Audio Out

Filter output

% sends out the filtered signal.