III Quick Guide of Installation
1. Modify the Protocol and the Address (jump over this section if no modification)
Take out the small metal cover on the bottom shown as dotted-lined part on Figure
3.1.1 to expose DIP switch of the address and the protocol shown as Figure 3.1.2. The
detailed drawing is shown as in Figure 3.1.1.
Figure 3.1.1
Figure 3.1.2
Figure 3.1.3
Shown as Figure 3.1.3, the 10-bit DIP stands for the addresses which can be from 0 to
1023. The 6-bit DIP stands for the protocols in which bits 1-4 mean the protocol
while bits 5-6 means the baud rate. Push the DIP downward means ON otherwise it
means OFF. For example the address in the figure means 1 while the protocol means
PELCO-D with the baud rate of 2400bps which can be found from the table.
Status of DIP Switch
Address
of PT
DIP-1 DIP-2 DIP-3 DIP-4
DIP-5
DIP-6
DIP-7
DIP-8 DIP-9 DIP-10
1
ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
2
OFF ON OFF OFF OFF OFF OFF OFF OFF OFF
3
ON ON OFF OFF OFF OFF OFF OFF OFF OFF
4
OFF OFF ON OFF OFF OFF OFF OFF OFF OFF
5
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
6
OFF ON ON OFF OFF OFF OFF OFF OFF OFF
7
ON ON ON OFF OFF OFF OFF OFF OFF OFF
8
OFF OFF OFF ON OFF OFF OFF OFF OFF OFF
9
ON OFF OFF ON OFF OFF OFF OFF OFF OFF
10
OFF ON OFF ON OFF OFF OFF OFF OFF OFF
11
ON ON OFF ON OFF OFF OFF OFF OFF OFF
12
OFF OFF ON ON OFF OFF OFF OFF OFF OFF
13
ON OFF ON ON OFF OFF OFF OFF OFF OFF
14
OFF ON ON ON OFF OFF OFF OFF OFF OFF
15
ON ON ON ON OFF OFF OFF OFF OFF OFF
3