![background image](/manuals/656468/11/background.png)
Selection of Communication
Protocol
Normal Baud
Rate
Type or Protocol
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
SAMSUNG
ON
OFF
OFF
OFF
OFF
ON
B01
ON
OFF
OFF
OFF
OFF
ON
NEON
ON
OFF
OFF
OFF
OFF
ON
Santachi
OFF
ON
OFF
OFF
OFF
ON
PELCO-D
ON
ON
OFF
OFF
OFF
OFF
PELCO-P/4800
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
PELCO-P/9600
PANASONIC
ON
OFF
ON
OFF
OFF
ON
Longcomity
OFF
ON
ON
OFF
OFF
ON
HUNDA600
ON
ON
ON
OFF
OFF
ON
LILIN
OFF
OFF
OFF
ON
OFF
ON
VICON
ON
OFF
OFF
ON
ON
OFF
MOLYNX
OFF
ON
OFF
ON
OFF
ON
KALATEL
ON
ON
OFF
ON
ON
OFF
VCL
OFF
OFF
ON
ON
OFF
ON
Reserved
ON
OFF
ON
ON
OFF
ON
ALEC
OFF
ON
ON
ON
OFF
ON
Ultrak
ON
ON
ON
ON
OFF
ON
6.Setup of the Baud Rate of Communication of the Pan/Tilt(later 2 bits of SW2)
Position of Dip-Switch
Baud Rate of Communication
1 2 3 4 5
6
2400 bps
OFF
OFF
4800 bps
ON
OFF
9600 bps
OFF
ON
19200 bps
ON
ON
7. Schematic Drawing of Dip-Switch for Reference:
AELC/9600Bps
ON
1
2
3
4
5
6
SAMSUNG/9600Bps
ON
1
2
3
4
5
6
PELCO-D/2400Bps
ON
1
2
3
4
5
6
PELCO-P/4800Bps
ON
1
2
3
4
5
6
PELCO-P/9600Bps
ON
1
2
3
4
5
6
B01/9600Bps
ON
1
2
3
4
5
6
8. Description of the Terminals
10