background image

 

 

 

 

 

 

After cleaning, partially opening and closing 
both the hot and cold service stops to flush 
valve body. 

Before installing a new replacement cartridge
apply some plumbers grease to the three (3) O‐
rings on the cartridge. 

Gently push and twist the cartridge into the 
body, until cartridge threads engage with valve 
body threads. 

Using a crescent wrench, securely tighten 
cartridge into place.  Proper tightening is about 
12 ft. lbs…similar to tightening a car spark plug.  

Make sure all volume controls are in the closed 
position before opening the service stops on the 
valve body.