California Faucets Pressure Balance Valve User Manual
California Faucets Accessories for water
PB-R_ii_110106.doc
Pg
1
PB - R
½” Pressure Balance Valve Rough
Installation Instructions
PB-R Flowrate vs Pressure
0
1
2
3
4
5
6
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75
Pressure (PSI)
Fl
o
w
ra
te
(
G
P
M
)
Tub Outlet Flow
Shower Outlet Flow (no showerhead)
IMPORTANT: Read all instructions prior to installation and provide copy of instructions to consumer.
WARNING: This valve is factory set to deliver water at the highest temperature possible. It is the installer’s responsibility to properly
set the desired and/or required maximum temperature setting to prevent risk on scalding or other severe injury prior to consumer use.
The installer is responsible for adjusting maximum temperature setting according to TO-PBL-XX ½” Pressure Balance Trim Installation
Instructions.
Operating Specifications:
Recommended Supply Pressure:
20 to 70 psi
*†
Recommended Hot Water Supply Temperature:
120 to 140°F
‡
Nominal Flow Rate @ 60 psi:
5.0 gpm (tub outlet)
4.2 gpm (shower oulet)
*
Operating pressures between hot and cold supplies should vary no more than 5 psi.
†
If water pressure exceeds 70 psi, install a Pressure-Reducing Valve (RPV).
‡
Follow all applicable local plumbing codes when setting the temperature on valve and water heater.
CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED
BY A LICENSED PROFESSIONAL
Body
“S”
Shower
Outlet
“C”
Cold
Inlet
“H”
Hot
Inlet
Tub Port
Plug
Valve
Mudguard
Stem Protector
Screw
Stem
Protector
Mounting Tab
(4)
Integral
Service/Check
Stop
(2)
“T”
Tub
Outlet