The Channel Status column has three states:
OK
, Unassigned, and
Error
. The Status will update as changes
are made to the Stereo Link and Slot Assignment columns for each channel, and as Mixer Configurations
are loaded from disk for editing.
A configuration being edited with the three channel Status states is shown.
The
OK
Status indicates that a mix channel’s network slot assignment has no conflicts with the other mix
channel button assignments in the current Mixer Configuration.
When the channel’s Status reads Unassigned, this indicates that no network slot is currently assigned
to the channel button. Mixer Configurations may be saved with some channels set to Unassigned, but
note that at least one of the mix channel buttons (or the Dual Profile Channel) must be assigned to use
a network slot before a Mixer Configuration can be saved. The Save function will be unavailable until all
channel conflicts are resolved and at least one mix channel button is assigned to a network slot.
P
N
ote
:
Any Channel Buttons that are Unassigned will not be able to be selected when the A360
Personal Mixer is in Custom mode.
The red
Error
status indicates that a channel has a conflict—this is usually caused during editing by
assigning the same network slot (or pair, if stereo) to more than one channel button. A Mixer Configuration
cannot be saved until all conflicts are resolved.