Visor and non-visor, 1small, indoor yr
40
Warning
Visor and Non-Visor
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
3
2
Sheet 1 of 2
mount fixtures vertically.
Installation Instructions
Vault
C-Scroll
Roundel
These installation instructions are valid with the above Ametrix styles.
1
Small, INDOOR
YR
(Yoke mount, Remote ballast)
ADY071442 Rev B (ECN80481)
mounting plate
Using #8-32 mounting screws (by others)
2.
screw and remove
secure mounting plate to J-box.
1. Loosen vertical set
Mounting plate
Fixing mounting plate to J-box
Fixture head and yoke
Attaching fixture head and yoke to
mounting plate
set screw
#10-32
Exploded view and part call-out
Mounting
plate
J-box
(by others)
Vertical
(by others)
#8-32 Mounting
screws
Fixture head
2.
Aiming the fixture
indicator
re-tighten end screws to secure the position.
Yoke arm Indicator
an additional 10-degrees.
When the fixture head is adjusted to the desired angle,
1. To aim the fixture, loosen both #10-32 end screws. When
the PointGrab
TM
system indicators are lined up, the slope
of the lens face is 40-degrees. Each subsequent notch is
#10-32 End
screw
#10-32 Vertical
set screw
of mounting plate.
Hook yoke and fixture
head on lower flange
1. Attach wires ensuring all connections are properly matched.
2. Angle yoke behind bottom flange on mounting plate and
press together.
3. Secure fixture using vertical set screw.