OEM Controls CANBus Product Line User Manual
Page 34

OM-17288
CANBus USERS MANUAL
Page 34 of 38
Revision C
GJO*07-12-06
ORIGINAL
Environment
-Temp:-40 - +70C operating
Protection: High performance silicone conformal coating
Module sealed and tested to IP-65 or greater
EMC
Compliance
-Radiated
Immunity:
EN 61000-4-3:1995, 30V/m
-ESD:
IEC
61000-4-2:1995
-Electrical Fast Transient:
IEC
61000-4-4:1994
-Surge
Immunity:
IEC61000-4-5:1995
-Conducted Immunity:
IEC
61000-4-6:1996
-Radiated Emissions:
EN 55011:1998, Class B
-Radiated Emissions:
EN 55022:1998, Class B
Firmware
-Upgradeable via the RS232 port