10.0 Specifications
Inputs
-Analog (Voltage) Inputs (Can also be factory configured for sinking or
sourcing digital inputs)
11 Bit Input Option (0-10vdc)
Resolution= 11 Bits– Each input is capable of commanding an
output channel with 2,000 discreet output levels
-Digital Inputs can be factory configured for Sinking or Sourcing operation
Outputs
-Current regulated 3 Amp PWM or Digital sourcing outputs
Current regulated to ± 5% for system voltage variation of ± 25% and valve
resistance increase of 0 to 50%
-Proportional Outputs can be calibrated for two separate PWM frequencies
Outputs 1 through 4 calibrated with PWM frequency A
Outputs 5 through 8 calibrated with PWM frequency B
-11 bit resolution - Each output is capable of providing 2,000 discreet
output
levels
-PWM frequency range: 60-250 Hz or 33-250 Hz( If OCO-2 Module )
-Proportional PWM or digital sourcing 3 Amp.
-14 bit resolution - Each PWM output is capable of providing 20,000
discreet output levels
Human Machine Interface
-LCD
Display
2 lines @ 16 characters for system operation and error codes
Low
temperature
display
-Membrane Keypad (4 buttons) for calibration– Intuitive menu system
works in conjunction with LCD display which allows the operator to choose
between the following parameters
Calibration
and
Adjustment
CAN Bus system state
Application
state
Software
Information
IO
Status
Indication
Communication
-Standard Protocol CANopen
Future/Optional
Protocol
-J1939