beautypg.com

8 rs232 – DVR systems DVRxx04LE-A Series User Manual

Page 29

background image

29

z

Please parallel connect COM end and GND end of the alarm detector (Provide external

power to the alarm detector).

z

Please parallel connect the Ground of the DVR and the ground of the alarm detector.

z

Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)

z

Use the same ground with that of DVR if you use external power to the alarm device.

Figure 3-8

3.7.3 Alarm Output Port

z

Provide external power to external alarm device.

z

To avoid overloading, please read the following relay parameters sheet carefully.

z

RS485 A/B cable is for the A/B cable of the PTZ decoder.

Relay Specification

Model:

JRC-27F

Material of the
touch

Silver

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Rating

Resistance

Load)

Maximum switch currency

1A

Between touches with same
polarity

1000VAC 1minute

Between touches with different
polarity

1000VAC 1minute

Insulation

Between touch and winding

1000VAC 1minute

Surge voltage

Between touches with same
polarity

1500V (10×160us)

Length of open
time

3ms max

Length of close
time

3ms max

Mechanical

50×106 times (3Hz)

Longevity

Electrical

200×103 times (0.5Hz)

Temperature

-40℃ ~+70℃

3.8 RS232